The Blue Line range of Flue Gas Combustion Analysers
The Eurolyzer Multi Fuel Domestic analsyer has a unique 5 year sensor unlike any other instrument on the market. As well as measuring for O2, CO, CO2, draft, temperature and efficiency you have the added capability of a fast printer, so you can keep results and give results to clients.
The instrument has Bluetooth and an SD card options for data storage for pulling together statistics at the end of your day.
The instrument boasts a bright coloured screen with easy to use IPOD like touch rotary keypad system, making this instrument a joy to use.
The entire Blue Line range of Combustion Analysers complies with BS EN50379 (parts 1,2 and 3) legislation.
An optional NO measurement is available. Excess Air %, stack loss %, CO/Co2 ratio and differential pressure mean you can configure boiler plant to optimum conditions in seconds.
Measured values, depending on equipment
O2, CO/H2, Flue gas temperature, combustion air temperature,
draught, pressure
Calculated values, depending on equipment
CO undiluted, Lambda, CO2, efficiency (Eta), temperature
difference, pressure difference Eta-BW (for combustion systems),
flue gas losses (qA), dewpoint
Input possibilities, depending on equipment
Sutt figure, oil derivatives, customer No., boiler temperature
Measuring ranges
Flue gas temperature (incl. separate differential
pressure measurement)
Measuring range: 0 °C/+1000 °C
Resolution: 1 °C
Accuracy: ± 1 °C + 1 digit (up to 300 °C)
± 1% of meas. value (above 300 °C)
Thermoelement: NiCr-Ni (Type K)
External wall or air temperature
Measuring range: -20 °C/+200 °C
Resolution: 0,1 °C
Accuracy: ± 3 °C + 1 digit (-20,0 to 0,0 °C)
± 1 °C + 1 digit (-0,1 to +200,0 °C)
Thermoelement: NiCr-Ni (Typ K)
Draught/Differential pressure
Measuring range: ± 50 hPa (draught)/± 130 hPa (diff.-pressure)
Accuracy: ± 2 Pa (up to ± 2 hPa)
± 1% of meas. value (up to ± 50 hPa)
± 1,5% meas. value (above ± 50 hPa)
Resolution: 1 Pa (= 0,01 hPa)
O2-Measurement
Measuring range: 0 ... 21 vol.-%
Resolution: 0,1 vol.-%
Accuracy: ± 0,2 vol.-% of meas. value
CO2-Determination
Indicating range: 0 ... CO2 max.
Resolution: 0,1 vol.-%
Accuracy: ± 0,2 Vol.-%
CO-Measurement
Measuring range: 0 ... 5000 ppm (nom.)/0 ... 9999 (max.)
Resolution: 1 ppm
Accuracy: ± 5 ppm (up to 50 ppm)
± 5% of meas. value (above 50 ppm)
Display
TFT colour monitor
Date Communication
USB-interface via cable
Wireless infra-red printer interface
Bluetooth (optional)
Memory
Micro-SD-card (Option: std. commercial up to max. 4 GB)
Power Supply
NiMH rechargeable battery 6V/2Ah,
external mains adaptor and charger
Protective Sleeve with Magnet
Soft plastic
Connections
Draught/Pressure: 7 mm diam
Gas: 8 mm diam
Housing
Mineral fibre plastic
Temperature
Plug connector system for
NiCr-Ni thermoelements (Type K)
Approvals
Acc. to BlmSchV and KUO as well as EN 50379-2
Weight (instrument only)
approx. 400 g
Instrument Variants
Eurolyzer ST for measurement of O2, CO
and (differential) temperature (Pt.No. 69332)
EUROLYZER ST for measurement of O2, CO,
(differential) temperature, draught (Pt.No. 69333)
EUROLYZER ST for measurement of O2, CO2, (differential)
temperature, (differential) pressure, draught (Pt.No. 69334)
Scope of Delivery
EUROLYZER ST, incl. of calibration protocol, mains adaptor,
flue gas probe, condensate filter cartridge, ambient air
sensor, connector set for gas fittings, protective sleeve with
magnet, aluminium instrument case
Optional Extras
Bluetooth interface, Micro-SD-Memory Card, Printer