Blue Line Maxilyzer Flue Gas Analyser

Product Information

Industrial flue gas analysis requires measurement of environmental as well as traditional combustion gasses. This may require a heated probe and controller to protect the gas sample and give accurate measurement of NO, NO2, SO2, O2, CO, CO2, temperature and efficiency.

An integrated printer gives you a hand copy record.

Bluetooth and SD card options give you enhanced data handling.

The Maxilyzer's rugged, Pelican style case withstands the  harsh working environments where measurements are taken.

As well as the integrated printer a flue gas treatment facility with high capacity impinger and filter is also built in.

The new Maxilyzer PLUS also incorporates a Peltier cooler to allow control of a heated probe. This ensures that environmental gas measurement including NO.NO2 and SO2 are consistently accurate.Traditional combustion measurement for O2, CO, flue gas temperature, excess air %, combustion efficiency % and draft are provided.

Shawcity are the sole distributor for this product within the UK!

Get pricing or request demonstration

 

Product features

  • Flue Gas Analysis
  • Up to six sensors
  • Flue Gas Temperature
  • Ambient Temperature
  • Draught/differential pressure
  • Measures Oxygen,Carbon Dioxide, Carbon Monoxide as standard
  • Other optional sensors
  • Multi-tasking mode
  • Bluetooth and SD options
  • Rugged pelican style case
  • Integrated printer for hand held records
  • Fully complies with BS EN50379 Pt II

Technical Specifications

 

Flue gas temperature

Measuring range: 0 °C/+1,000 °C
Resolution: 1 °C
Thermocouple: NiCr-Ni (Type K)

Ambient/air temperature

Measuring range: -20 °C/+200 °C
Resolution: 0.1 °C
Thermocouple: NiCr-Ni (Type K)

Draught/differential pressure

Measuring range: ±130 mbar (max. ±150 mbar)
Resolution: 0.01 hPa

O2 measurement (electro-chemical measuring cell)

Measuring range: 0/21 Vol.-%
Resolution: 0.1 Vol.-%

CO2 (calculated from O2)

Measuring range: 0/CO2 max.
Resolution: 0.1 Vol.-%

CO measurement

(electro-chemical measuring cell,
with H2 compensation)
Measuring range: 0/4,000 ppm
Resolution: 1 ppm

Options

CO measurement, solid fuels (without H2 compensation)

Measuring range: 0/2.0 Vol.-% (20,000 ppm) Resolution: 0.01 Vol.-%

NO measurement (electro-chemical measuring cell)

Measuring range: 0/2,000 ppm Resolution: 1 ppm

SO2 measurement (electro-chemical measuring cell)

Measuring range: 0/2,000 ppm Resolution: 1 ppm

Weight

approx. 3 kg

Dimensions W x H x D

275 x 115 x 250 mm

 

 

 