Because many users want an analyser to meet the needs for environmental as well as safe and efficient operation, meausurement of NO, NO2,SO2 as well as high range CO is an option.
Standard measurements for O2, CO, CO2 temp and efficiency are monitored on this rugged industrial combustion analyser.
Excess air %, draft and differential pressure are also provided making Multilyzer the most comprehensive of hand held combustion analysers.
Data is sent to a remote printer at the push of a button. An SD card permits data collection and storage for later retrieval.
The Multilyzers industrial design demanded industrial quality probe and hose assembly. The rugged sample line includes a condensate collection impinger and filter assembly. This allows instruments to continue operating for long periods before pausing for simple preventive maintenance.
Shawcity Limited are the sole distributor for this product within the UK!
Technical Specifications
Flue gas temperature (incl. separate differential
temperature measurement)
Measuring range: 0 °C/1,000 °C
Resolution: 1 °C
Thermocouple: NiCr-Ni (Type K)
Ambient/air temperature
Measuring range: -20 °C/+200 °C
Resolution: 0.1 °C
Thermocouple: NiCr-Ni (Type K)
Draught/differential pressure
Measuring range: ±70 hPa (nominal/±130 hPa (max.)
Accuracy: ±1% of meas.value/±2% of meas.value
Resolution: 0.01 hPa
O2 measurement
Measuring range: 0/21 Vol.%
Resolution: 0.1 Vol.%
Accuracy: ±0.2 Vol.% of meas.value
CO2 calculated value
Measuring range: 0/CO2 max.
Resolution: 0.1 Vol.%
Accuracy: ±0.2 Vol.%
CO measurement (with H2 compensation)
Measuring range: 0/4,000 ppm
Resolution: 1 ppm
Accuracy: ±3 ppm (up to 20 ppm)
±5 % of meas.value
(above 20 ppm)
Options
NO measurement
Measuring range: 0/2,000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm
(up to 50 ppm)
±5 % of
meas.value
(above 50 ppm)
CO measurement solid fuels
Measuring range: 0/2.0 Vol.%
(or 20,000 ppm)
Resolution: 0.01 Vol.%
Accuracy:
±5 % of meas.value
±1 digit
SO2 measurement
Measuring range: 0/2,000 ppm
Resolution: 1 ppm
Accuracy: ±10 ppm (up to 150 ppm)
±5 % of meas.value
(above 150 ppm)
NO2 measurement
Measuring range: 0/200 ppm
Resolution: 1 ppm
Accuracy: ±10 ppm (up to 50 ppm)
±10% of meas.value